Sennheiser EM 300 G3 Manuál s instrukcemi

Procházejte online nebo si stáhněte Manuál s instrukcemi pro Obousměrná rádia Sennheiser EM 300 G3. Sennheiser EM 300 G3 Instruction manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Instruction manual

SK 300Instruction manual

Strany 2

8Putting the bodypack transmitter into operationPutting the bodypack transmitter into operationInserting the batteries/accupackFor powering the bodypa

Strany 3 - Contents

9Putting the bodypack transmitter into operationAttaching and positioning the microphonesME 2왘 Use the microphone clip 씍 to attach the microphone to c

Strany 4 - Important safety instructions

10Putting the bodypack transmitter into operationAttaching the bodypack transmitter to clothingYou can use the belt clip 씎 to attach the bodypack tran

Strany 5 - The frequency bank system

11Using the bodypack transmitterUsing the bodypack transmitterTo establish a transmission link, proceed as follows:1. Switch the receiver on (see the

Strany 6 - Areas of application

12Using the bodypack transmitterTo activate the RF signal:Deactivating the lock mode temporarilyYou can activate or deactivate the automatic lock mode

Strany 7 - Delivery includes

13Using the bodypack transmitter왘 Slide the MUTE switch 쐇 to the left, to the position MUTE.The bodypack transmitter reacts as indicated in the table.

Strany 8 - Product overview

14Using the operating menuUsing the operating menuThe buttonsOverview of the operating menuButton Function of the buttonPress the ON/OFF button• Switc

Strany 9 - Overview of the displays

15Using the operating menuWorking with the operating menuBy way of example of the “Sensitivity” menu, this section describes how touse the operating m

Strany 10 - Charging the accupack

16Using the operating menuCanceling an entryTo return to the last edited menu item:Exiting a menu itemTo return to the next higher menu level:To direc

Strany 11

17Adjusting settings via the operating menuAdjusting settings via the operating menuThe main menu “Menu”Adjusting the input sensitivity – “Sensitivity

Strany 13

18Adjusting settings via the operating menuOverview of the frequency banks and channels:When setting up multi-channel systems, please observe the foll

Strany 14 - Muting the audio signal

19Adjusting settings via the operating menuThe extended menu “Advanced Menu”Setting transmission frequencies and frequency banks – “Tune”When you have

Strany 15 - Selecting a standard display

20Adjusting settings via the operating menuSetting the mode for the MUTE switch and the RMS 1 external mute switch – “Mute Mode”The “Push to mute” and

Strany 16 - Using the operating menu

21Adjusting settings via the operating menuAdjusting the transmission power – “RF Power”Via the “RF Power” menu item, you can adjust the transmission

Strany 17 - Sensitivity

22Adjustment tipsAdjustment tipsSynchronizing the bodypack transmitter with a receiverWhen synchronizing the bodypack transmitter with a receiver, ple

Strany 18 - Exiting a menu item

23If a problem occurs ...If a problem occurs ...If a problem occurs that is not listed in the above table or if the problemcannot be solved with the p

Strany 19 - The main menu “Menu”

24SpecificationsSpecificationsIn compliance withRF characteristicsModulation wideband FMFrequency ranges 516–558, 566–608, 626–668, 734–776, 780–822,

Strany 20 - Entering a name – “Name”

25SpecificationsApproved byMicrophonesConnector assignment3.5 mm jack plugPolar diagrams and frequency response curves of the microphonesCanada Indust

Strany 21 - “Stored”

26Manufacturer DeclarationsManufacturer DeclarationsWarrantySennheiser electronic GmbH & Co. KG gives a warranty of 24 months on thisproduct.For t

Strany 22 - AF On/Off

27Manufacturer DeclarationsStatements regarding FCC and Industry Canada This device complies with Part 15 of the FCC Rules and with RSS-210 ofIndustry

Strany 23 - Advanced

1ContentsContentsImportant safety instructions ...2The SK 300 G3 bodypack tra

Strany 26 - Specifications

Sennheiser electronic GmbH & Co. KGAm Labor 1, 30900 Wedemark, Germanywww.sennheiser.comPrinted in GermanyPubl. 01/09529670/A01

Strany 27 - Connector assignment

2Important safety instructionsImportant safety instructions• Read this instruction manual.• Keep this instruction manual. Always include this instruct

Strany 28 - CE Declaration of Conformity

3The SK 300 G3 bodypack transmitterThe SK 300 G3 bodypack transmitterThe SK 300 G3 bodypack transmitter is part of the evolution wireless seriesgenera

Strany 29

4The SK 300 G3 bodypack transmitterAreas of applicationThe bodypack transmitter can be combined with the EM 300 G3 rack-mount receiver.The EM 300 G3 r

Strany 30

5Delivery includesDelivery includesThe packaging contains the following items:1 SK 300 G3 bodypack transmitter2 AA size batteries, 1.5 V1 instruction

Strany 31

6Product overviewProduct overviewOverview of the SK 300 bodypack transmitter쐃 Microphone/instrument input (MIC/LINE), 3.5 mm jack socket, lockable쐇 MU

Strany 32

7Product overviewOverview of the displaysAfter switch-on, the bodypack transmitter displays the standard display“Frequency/Name”. For further illustra

Komentáře k této Příručce

Žádné komentáře